CJX2(FNC2) Series AC Contactor |
|
|
|
● Application |
CJX2(FNC2) Series AC Contactor are suitable for 50/60Hz,rated insulation voltage
up to 1000V, rated operation current 9~330A under AC-3 duty.lt is mainly used
for making/breaking electric circuits at a long distance & for frequent starting & controlling A.C. Motors.lt is used in combination with thermal relay to compose
a magnetic motor starter.The products accord with as IEC60947-4-1.
|
 |
●Technical Data |
Rated operational voltage & rated insulation voltage of the contactor see table 1. |
| TYPE |
CJX2-9-95 |
CJX2-115-330 |
| Rated operating voltage(V) |
220-660 |
220-1000 |
| Rated insulation voltage(V) |
660 |
1000 |
Conventional thermal current and rated operating current and maximum power of controllabe 3-phase
A.C. motor under AC-3 duty see Table 2.
| Type |
Conventional |
Rated operating current(A) |
Power of controllable motor(KW) |
| 380V |
660V |
|
380V |
660V |
|
| CJX2-9 |
20 |
9 |
6.6 |
|
380V |
660V |
|
| CJX2-12 |
20 |
12 |
8.9 |
|
380V |
660V |
|
| CJX2-16 |
32 |
16 |
10.6 |
|
380V |
660V |
|
| CJX2-25 |
40 |
25 |
18 |
|
380V |
660V |
|
| CJX2-32 |
50 |
32 |
21 |
|
380V |
660V |
|
| CJX2-40 |
60 |
40 |
34 |
|
380V |
660V |
|
| CJX2-50 |
80 |
50 |
39 |
|
380V |
660V |
|
| CJX2-63 |
80 |
63 |
42 |
|
380V |
660V |
|
| CJX2-80 |
125 |
80 |
49 |
|
380V |
660V |
|
| CJX2-95 |
125 |
95 |
49 |
|
380V |
660V |
|
| CJX2-115 |
200 |
115 |
65 |
40 |
380V |
660V |
65 |
| CJX2-150 |
200 |
150 |
80 |
50 |
380V |
110 |
65 |
| CJX2-185 |
275 |
185 |
95 |
65 |
380V |
110 |
100 |
| CJX2-225 |
175 |
225 |
115 |
80 |
380V |
129 |
100 |
| CJX2-265 |
315 |
265 |
150 |
95 |
380V |
160 |
147 |
| CJX2-330 |
380 |
330 |
185 |
115 |
380V |
220 |
160 |
A.C. motor under AC-3 duty see Table 2.
| TYPE |
Frequency of operation(1/h) |
Mechanical endurance(x104) |
Bectrical endurance (x104) |
| CJX2-9~25 |
1200 |
1000 |
100 |
| CJX2-32~40 |
600 |
800 |
80 |
| CJX2-50~63 |
60 |
| CJX2-80~95 |
600 |
| CJX2-115~150 |
1000 |
120 |
| CJX2-185~225 |
600 |
100 |
| CJX2-185~330 |
80 |
Voltage range of control coil:(0.85-1.1)US tECHNICAL DATE OF THE AUXILIARY CONTACTS SEE TABLE 4.
| Utilization category |
AC-15 |
DC-13 |
| Rated insulation voltage(V) |
660 |
| Rated operating voltage(V) |
380 |
220 |
| Conventional thermal current(A) |
10 |
| Rated operating current(A) |
0.95 |
0.15 |
| Control capacity |
360VA |
330W |
Voltage of control coil and power see Table 5
| TYPE |
Control voltage(V) |
Control capacity |
| Starting(VA) |
Attracting(VA) |
| CJX2-9~16 |
24,36,48,110,127,220,380 |
60 |
7 |
| CJX2-25~32 |
90 |
7.5 |
| CJX2-40~95 |
200 |
20 |
| CJX2-115~150 |
110,127,220,380 |
660 |
54 |
| CJX2-185~225 |
966 |
66 |
| CJX2-265 |
110,127 |
720 |
10 |
| CJX2-330 |
220,380 |
840 |
12 |
|
|
| |
|
|
|
|
|